Message: Return type of CI_Session_files_driver::open($save_path, $name) should either be compatible with SessionHandlerInterface::open(string $path, string $name): bool, or the #[\ReturnTypeWillChange] attribute should be used to temporarily suppress the notice
Message: Return type of CI_Session_files_driver::close() should either be compatible with SessionHandlerInterface::close(): bool, or the #[\ReturnTypeWillChange] attribute should be used to temporarily suppress the notice
Message: Return type of CI_Session_files_driver::read($session_id) should either be compatible with SessionHandlerInterface::read(string $id): string|false, or the #[\ReturnTypeWillChange] attribute should be used to temporarily suppress the notice
Message: Return type of CI_Session_files_driver::write($session_id, $session_data) should either be compatible with SessionHandlerInterface::write(string $id, string $data): bool, or the #[\ReturnTypeWillChange] attribute should be used to temporarily suppress the notice
Message: Return type of CI_Session_files_driver::destroy($session_id) should either be compatible with SessionHandlerInterface::destroy(string $id): bool, or the #[\ReturnTypeWillChange] attribute should be used to temporarily suppress the notice
Message: Return type of CI_Session_files_driver::gc($maxlifetime) should either be compatible with SessionHandlerInterface::gc(int $max_lifetime): int|false, or the #[\ReturnTypeWillChange] attribute should be used to temporarily suppress the notice
CT-square shaped towers cool the re-cycled water. The towers blend easily with architectural surroundings, giving a unique aesthetic appearance.
Designed to cool industrial re-cycled process water from temperature of 50 degrees to temperature of 4 plus the prevailing Wet Bulb temperature of the region. The design incorporate the static spray nozzle distribution to atomize water in to a mist state and ensure uniformity in water dispersion and are easy to maintain even during the tower operations.
The hot water from the application is dispersed uniformly over the wet deck fill by means of static spray non clog nozzles. Simultaneously, air is induced through the fill media thus taking away the latent heat from the water passing through the fill media. Portion of water evaporated, removes the heat from the remaining water. The warm moist air is drawn through the fan deck is discharged to the atmosphere. Cold water, collected at the collection sump, is re-circulated to the heat source.
The tower designs incorporates a static distribution setup, located above the fill media. Hot water form the application is circulated to the distribution header from which they are dispersed over the fill media by no. of non-clog static nozzles, fitted to the branch pipe of the main header. Water when forced ( 1 to 1.5 kg/scm) through the distribution setups is atomized and sprayed over the fill media. The fan that is coupled directly to the motor draws air across the fill media vertically and in the process takes away the heat from the water. Cold water is collected at the collection sump having the outlet connection through which cold water is circulated to the application. The spray losses are minimized by using adequate drift eliminators. The distinguishing features of our product are compact design Honey comb type PVC fills, with varying flute sizes, to provide maximum contact surface area and heat transfer surface per unit volume.